Ion Chromatography system FM-ICS-A100

Ion Chromatography system FM-ICS-A100 is designed to deliver unparalleled performance in ion analysis. Column heater maintains a stable temperature for optimal performance, with a controlling accuracy of ± 0.1 °C. Integrated with dual-channel system for independent operation of cation and anion channels. This enables simultaneous detection without any interference. With its advanced features and extensive capabilities, it is the ultimate solution for high-performance in diverse analytical settings.

Maximize Your Machine Potential

At Dyrec, we are committed to empowering your business with the latest solutions. Our top-quality rotary joints are designed to optimize the performance of your equipment.

Take the next step toward success by contacting us or downloading our comprehensive product guide. Your journey toward success begins here.

Description

Features

  1. Cutting-edge ion chromatography system
  2. Advanced eluent thermal buffer system
  3. High-pressure, low-pulse pump technology
  4. High-performance conductivity detector
  5. Temperature stability and control
  6. Self-regeneration electrolytic suppressors
  7. Built-in leakage sensors
  8. Chemically inert design
  9. Low-pressure degassing technology

Applications

  • Ion Chromatography system is widely used across environmental analysis, pharmaceuticals and biotechnology, food and beverage, chemicals, petrochemicals, water treatment, healthcare and clinical laboratories, agriculture, etc.
Eluent TypesKOH, NaOH, LiOH, MSA
Eluent Concentration Range0.1 to 100 mM
Eluent Generator Concentration Increment0.1 mM
Eluent Generator Flow Rate Range0.1 to 5.0 ml/min
Eluent Generator Maximum Pressure30 Mpa
Eluent Generator Minimum Pressure5 Mpa
Eluent Generator Accuracy of Gradient0.0015
Vacuum Degree-70 kPa
Vacuum Degasser Internal Volume300 μL
Vacuum Degasser Flow RateMaximum 10 ml/min
Degassing Efficiency90% at 1.0 ml/min
Degassing Volume7.5 ml
Flow Path MaterialChemically inert, metal-free PEEK, compatible with aqueous eluents of pH 0 to 14 and reversed-phase solvents
Pump TypeTwo-piston tandem advection pump
Maximum Pressure of Pump42 Mpa
Pump Pressure Ripple≤0.5%
Flow Rate Range of Pump0.001 to 9.999 mL/min
Pump Flow Precision≤0.1%
Pump Flow Accuracy≤0.1%
External Diameter of the Tube1/16″
Column heater operating temperature rangeAmbient +5 to 60 ℃
Column heater temperature accuracy±0.1 °C
Column heater temperature stability≤0.1 ℃/h
Columns Supported2, 3, 4, 5 mm ID (up to 250 mm length, with 50 mm guard column)
Conductivity Detector typeAuto-range conductivity detector
Conductivity Detector Cell Volume≤0.8 μL
Detection Range0 to 50000 μS/cm
Conductivity Detector Resolution≤0.0020 nS/cm
Conductivity Baseline Noise≤0.0005 μS/cm
Conductivity Detector Electronic noise0.02 nS
Detector Baseline Drift≤0.005 Μs
Conductivity Detector Maximum Pressure10 Mpa
Operating Temperature RangeAmbient +5 ℃ to 60 ℃
Controlling Temperature Accuracy±0.01 ℃
Temperature Compensation1.7 % / ℃
Maximum Pressure Handling10.0 MPa
Linear Range of Conductivity Measurement≥10 3
Instrument Linearity for Conductivity≥0.999
Quantitative Repeatability in Conductivity≤0.5%
Qualitative Repeatability in Conductivity≤0.2%
Minimum Detectable Concentration (Cl-)≤0.0004 µg/mL
Minimum Detectable Concentration (Li+)≤0.0001 µg/mL
Suppressor typeSelf-Regeneration electrolytic micro-membrane
Suppressor maximum pressure6 MPa
Suppressor void volume< 40 μL (4 mm), < 15 μL (2 mm)
Power350 W
Exterior dimension (L × W × H)500 × 500 × 760 mm
Net Weight48 Kg
Gross Weight73 Kg

Reviews

There are no reviews yet.

Be the first to review “Ion Chromatography system FM-ICS-A100”

Your email address will not be published. Required fields are marked *

Produk Lainnya

Send Manual