Benchtop Multi-parameter Water Quality Meter FM-BMW-A100 features a pH measurement range of -2.000 to 20.000, ensuring reliable water analysis. It operates within a temperature range of 0 to 105°C, providing optimal performance under varying conditions. It measures dissolved oxygen with a range of 0.00 to 20.00 mg/L for consistent results. It features a TDS range of 0 to 10.00, designed to deliver accurate readings with precise calibration. Designed with an LCD, it provides clear readings and easy operation for accurate monitoring.
At Dyrec, we are committed to empowering your business with the latest solutions. Our top-quality rotary joints are designed to optimize the performance of your equipment.
Take the next step toward success by contacting us or downloading our comprehensive product guide. Your journey toward success begins here.
| pH Range | -2.000 to 20.000 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH, selectable |
| pH Accuracy | ±0.002 pH |
| pH Calibration Points | 1 to 5 points |
| pH Buffer Options | USA / NIST / DIN / 2 custom buffers |
| ORP Range | -1999.9 to 1999.9 mV |
| ORP Resolution | 0.1 / 1 mV, selectable |
| ORP Accuracy | ±0.2 mV |
| ORP Calibration Points | 1 point |
| Measurement Modes | Ion Concentration, Relative / Absolute mV |
| Ion Concentration Range | 0.00 to 19999 (depending on ISE range) |
| Ion Concentration Resolution | 0.001 / 0.01 / 0.1 / 1, automatic |
| Ion Concentration Accuracy | ±0.5% F.S. (monovalent), ±1% F.S. (divalent) |
| Ion Calibration Points | 2 to 5 points |
| Ion Calibration Solutions | 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000 |
| Ion Measurement Units | ppm, mg/L, mol/L, mmol/L |
| Conductivity Range | 0 to 20.00, 200.0, 2000 µS/cm; 20.00, 200.0 mS/cm |
| Conductivity Resolution | 0.001 / 0.01 / 0.1 / 1, automatic |
| Conductivity Accuracy | ±0.5% F.S. |
| Conductivity Calibration Points | 1 to 5 points |
| Conductivity Calibration Solutions | 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS |
| Temperature Coefficient | 0.0 to 10.0%/°C |
| Pure Water Compensation | Yes |
| Reference Temperature | 20°C / 25°C |
| Cell Constant | K=0.1 / 1 / 10 / Custom |
| TDS Range | 0 to 10.00, 100.0, 1000 ppm; 10.00, 200.0 ppt |
| TDS Resolution | 0.01 / 0.1 / 1, automatic |
| TDS Accuracy | ±1% F.S. |
| TDS Conversion Factor | 0.1 to 1.0 (default 0.5) |
| Salinity Range | 0.00 to 80.00 ppt / 0.00 to 42.00 psu |
| Salinity Resolution | 0.01 |
| Salinity Accuracy | ±1% F.S. |
| Resistivity Range | 0.00 to 20.00 MΩ |
| Resistivity Resolution | 0.01 |
| Resistivity Accuracy | ±1% F.S. |
| Dissolved Oxygen Range | 0.00 to 20.00 mg/L; 0.0 to 200.0% saturation |
| DO Resolution | 0.01 / 0.1, selectable |
| DO Accuracy | ±0.2 mg/L / ±2.0% |
| DO Calibration Points | 1 or 2 points |
| Pressure Correction | 60.0 to 112.5 kPa / 450 to 850 mmHg, manual |
| Salinity Correction | 0.0 to 50.0 g/L, manual |
| Temperature Range | 0 to 105°C / 32 to 221°F |
| Temperature Resolution | 0.1°C / °F |
| Temperature Accuracy | ±0.5°C / ±0.9°F |
| Temperature Offset Calibration | 1 point |
| Temperature Calibration Range | Reading ±10°C / °F |
| Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic |
| Hold Function | Manual / Auto-read measurement endpoint |
| Stability Criteria | Low / High |
| Calibration Due Alarm | 1 to 31 days or off |
| Memory | Stores up to 500 data sets |
| Output Interface | USB communication interface |
| Connector Types | BNC, 6-pin mini-DIN, 3.5 mm jack socket |
| Display | Custom LCD (125 × 100 mm) |
| Power Supply | 5 VDC power adapter |
| Operating Conditions | 0 to 50°C / 32 to 122°F, RH < 80% |
| Dimensions (W × D × H) | 210 × 188 × 60 mm |
| Packing dimension (W × D × H) | 300 × 250 × 200 mm |
| Net Weight | 1.5 kg |
| Gross Weight | 1.7 kg |